Strong points
• Lock actuated by motor
• Control unit : microprocessor with time delay
• Dead bolt for mechanical locking/unlocking by key
• Adjustable strike plate : in case door is not lined up properly
• Welded casing : protection against dust & manipulation
• Monitoring outputs :
- Bolt in/bolt out signal (locked/unlocked)
- Door position (closed/unclosed)
- On request : dead bolt position (mechanical locking/unlocking) detection for key unlocking
• Large choice of construction :
- Fail safe/fail secure - Mortice/surface mount With or without dead bolt.
• Bolt resisitance : 1300 daN
Operation
Electric function :
• Fail safe or fail secure configuration
• Automatic re-locking bymotorwhen door closes and at the end of set time delay
• In case door is not properly closed, motor will try to relock and bolt immediatelywill retract on contactwith obstacle, thus causing a clicking noise without diminishing life expectancy of motor
• Necessary to use our control unit DG 2740P
Mechanical function :
Mechanical opening both inside & outside :
• by key cylinder : to unlock electric bolt & to lock & unlock mechanical dead bolt
• by handle with push cylinder on fail secure model
• by electric buttom on fail safe model
Construction
Casing Zinc-plated steel
Bolt Solid brass
Strike plate Stainless steel
Door clearance 3-7 mm
Cylinder European cylinder - Other cylinders on request
Mounting : Vertical or horizontal at the top of the door or also in
the door frame (in this case, no power supply on door)
Electrical Specifications
• Supply 12 VDC (12V mini, 14V maxi)
• Current consumption Fail safe : 300 mA permanently
Fail secure : 300 mA in operation
Bolt position 500 mA max