Strong points
For electric locks
• Cut-outs in glass required
• Fail secure or fail safe
• Compatible with any access control : card reader, interphone, keypad etc…
• Automatic locking of the door
• Length to order
• Power supply with flexible door loop from the service leaf side
• Available for single & double doors
• Delivered with door loop and with a round cylinder
Formechanical locks
• 2 models :
- 1. Top or Bottom door rails with floor latch
- 2. Top or Bottom door rails with deadbolt lock
Operation
Exterior opening
• Electric opening with any access control system
• Mechanical opening with key (only for fail secure model)
Interior opening
• Push cylinder only for fail secure model
• Push Buttom for fail safe model
Construction
Strip lock Anodized aluminium (Polished brass or stainless steel also available)
Bolt Stainless steel
Height 125 mm
Cylinder Round cylinder KABA XPT
Electrical Specifications
Fail secure or fail safe operation
• Supply 12 VDC with door loop from the service door side only
• Consumption 2.5 Amp for fail safe
250 mA for fail secure
Scope of supply
- Exterior round cylinder (KABA XPT) for fail secure model only
- Interior push cylinder for fail secure model only
- Flexible door loop
- Interior push buttom for fail safe model