Strong points
• High burglarymechanical resistance due to its solid construction
Quality of the construction materials (high graded steel 20/10 cover
protected against
corrosion)
3 Bolts diameter 20 : resistance : 2000 daN for each bolt
- stroke : 24 mm
- locking force : 35 N
• Endurance & longevity
Tested for intensive use : 1 million openings for high traffic doors
Reliability of locking
-Motor allows a very fast locking & unlocking action
- A door positionmagnet detects the closed state of the door providing
immediate & automatic locking
• Efficientmanagement of information
Integrated microprocessor protected against :
- Polarity inversion
- Electrostatic discharges
- Shocks & vibration
And with following monitoring outputs :
- Time delay (adjustable from 1 to 30 s)
- Alarm buzzer (to detect defective locking)
- Bolt in/bolt out signal
- Door position
- Control of mechanical unlocking
- Detection of anomalies
- Anti-fraud system
• Simplifiedmaintenance
A diagnostic plug gives following information :
- Total number of manoeuvres (control of lock wear)
- Number of bolt obstructions (life duration of motor)
- Voltage variation (power failure)
• Choice of functions &mounting
- Fail safe or fail secure
- Surface mount
• Ease of use
- Interior mechanical unlocking by key or knurled knob
- Option on Fail secure model : electrical knob to unlock door
in case of emergency (interior side)
Operation
Entrance is electrically controlled by any type of access control
system and locking is automatic once door closing has been detected by magnetic
contact. A full range of monitorings ensures better electrical security. Mechanical
unlocking by cylinder & key is always possible from either side of the door.
Construction
Casing Steel 20/10
Bolt Stainless steel
Strike plate : Steel 25/10
Door clearance 4-9 mm
Cover Steel 20/10
Cylinder European cylinder
In option Extended lock cover to fit the entire door length
Electrical Specifications
• Supply
Nominal 13.6 VDC Tolerance 9 to 20 v
Out of tolerance, lock doesn’t operate
• Nominal current
200 m A - Maximal : 1.5 A (+/-10%)
• Power Consumption
On “stand-by” mode : 40 mA
At start up : 2 A during 0.1 secund
• Locking & unlocking time
1 secund
• Operating temperature
From -15° to 55°C